Fibrin glue augmentation for flexor tendon repair increases friction compared with epitendinous suture.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 24275055.
- Also identified by DOI 10.1016/j.jhsa.2013.10.010.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To compare the gliding resistance, repair gapping, and ultimate strength of a common suture construct with a modified construct with fibrin glue augmentation. Twelve human cadaveric flexor digitorum profundus tendons were transected and repaired with a 4-strand core suture. Specimens were divided into 2 groups and augmented with epitendinous suture (n = 6) or fibrin glue (n = 6). We compared gliding resistance, 2-mm gapping, and ultimate strength of the repaired tendon between groups. The linear stiffness, force to produce a 2-mm gap, and ultimate failure were similar in both repair methods. However, the 4-strand suture repair with fibrin glue augmentation displayed significantly higher gliding resistance compared with the 4-strand suture with a running epitendinous suture. The significantly increased gliding resistance associated with fibrin glue raises questions regarding the use of this material for flexor tendon repair augmentation. In a human cadaveric study, fibrin glue augmentation to zone II flexor tendon repairs significantly increased friction in the tendon sheath compared with an epitendinous suture.
Medical subject headings
- Compressive Strength
- Fibrin Tissue Adhesive
- Plastic Surgery Procedures
- Tendon Injuries