Bone cement embolism attached to central venous catheter.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 24318858.
- Also identified by DOI 10.1093/bja/aet413.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We report on a rare complication of poly(methyl methacrylate) (PMMA), injected into the spine, which then inadvertently leaked into the venous system. This resulted in an embolism of PMMA and produced a mass surrounding a triple lumen central venous catheter located in the superior vena cava. The catheter as well as the attached mass of PMMA was retrieved safely by cardiothoracic surgery. This case emphasizes the importance of prompt diagnosis and treatment and illustrates the need for close monitoring of patients undergoing any spinal surgery that includes vertebroplasty.
Medical subject headings
- Bone Cements
- Central Venous Catheters
- Polymethyl Methacrylate
- Pulmonary Embolism
- Vertebroplasty