How effective is multiple needle puncturing for medial soft tissue balancing during total knee arthroplasty? A cadaveric study.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 24360488.
- Also identified by DOI 10.1016/j.arth.2013.11.004.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We investigated the quantitative effect and risk factors for over-release during multiple needle puncturing (MNP) for medial gap balancing in varus total knee arthroplasty (TKA). Of the ten pairs of cadaveric knees, one knee from each pair was randomly assigned to undergo MNP in extension (E group), while the other knee underwent MNP in flexion (F group). The increased extension and 90° flexion gaps after every five needle punctures were measured until over-release occurred. The extension gap (< 4mm) and the 90° flexion gap (< 6mm) gradually increased in both groups. The 90° flexion gaps increased more selectively than did the extension gaps. MNP in the flexed knee, a narrow MCL, and severe osteoarthritis were associated with a smaller number of MNPs required to over-release.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Knee
- Knee Joint
- Osteoarthritis, Knee
- Punctures
Anatomy
- knee