Posterior reversible encephalopathy syndrome from induced hypertension during endovascular thoracoabdominal aortic aneurysm repair.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 24365121.
- Also identified by DOI 10.1016/j.jvs.2013.10.052.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Endovascular repair of thoracoabdominal aortic aneurysm has been increasingly performed using fenestrated and branched endografts. Spinal cord injury is a complication of complex endovascular aortic repair, especially in patients with extensive aortic involvement. Maneuvers commonly used to avoid spinal cord injury include cerebrospinal fluid drainage and induced hypertension. Posterior reversible encephalopathy syndrome is associated with abnormal cerebral autoregulation through endothelial and blood-brain barrier dysfunction; the pathophysiology involves vasogenic edema, and severe hypertension is a recognized trigger. We report on a patient who developed posterior reversible encephalopathy syndrome associated with induced hypertension used to prevent spinal cord injury during endovascular repair of a type II thoracoabdominal aortic aneurysm using fenestrated and branched stent grafts.
Medical subject headings
- Aortic Aneurysm, Thoracic
- Blood Vessel Prosthesis Implantation
- Endovascular Procedures
- Hypertension
- Posterior Leukoencephalopathy Syndrome
- Spinal Cord Injuries