Similar improvement in gait parameters following direct anterior & posterior approach total hip arthroplasty.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 24405621.
- Also identified by DOI 10.1016/j.arth.2013.11.021.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We compared gait parameters prior to, at 6 months and 1 year following total hip arthroplasty (THA) performed via direct anterior approach (DAA) and posterior approach (PA) by a single surgeon in 22 patients. A gait analysis system involving reflective markers, infrared cameras and a multicomponent force plate was utilized. Postoperatively, the study cohort demonstrated improvement in flexion/extension range of motion (ROM) (P = 0.001), peak flexion (P = 0.005) and extension (P = 0.002) moments with no differences between groups. Internal/external ROM improved significantly in the DAA group (P = 0.04) with no change in the PA group. THA performed via DAA and PA offers similar improvement in gait parameters with the exception of internal/external ROM which might be related to the release and repair of external rotators during PA THA.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Gait
- Osteoarthritis, Hip
Anatomy
- hip