Abdominal aortic intimal flap motion characterization in acute aortic dissection: assessed with retrospective ECG-gated thoracoabdominal aorta dual-source CT angiography.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 24503676.
- Also identified by DOI 10.1371/journal.pone.0087664 and PMC identifier 3913653.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To evaluate the feasibility of dose-modulated retrospective ECG-gated thoracoabdominal aorta CT angiography (CTA) assessing abdominal aortic intimal flap motion and investigate the motion characteristics of intimal flap in acute aortic dissection (AAD). 49 patients who had thoracoabdominal aorta retrospective ECG-gated CTA scan were enrolled. 20 datasets were reconstructed in 5% steps between 0 and 95% of the R-R interval in each case. The aortic intimal flap motion was assessed by measuring the short axis diameters of the true lumen and false lumen 2 cm above of celiac trunk ostium in different R-R intervals. Intimal flap motion and configuration was assessed by two independent observers. In these 49 patients, 37 had AAD, 7 had intramural hematoma, and 5 had negative result for acute aortic disorder. 620 datasets of 31 patients who showed double lumens in abdominal aorta were enrolled in evaluating intimal flap motion. The maximum and minimum true lumen diameter were 12.2 ± 4.1 mm (range 2.6 ∼ 17.4) and 6.7 ± 4.1 mm (range 0 ∼ 15.3) respectively. The range of intimal flap motion in all patients was 5.5 ± 2.6 mm (range 1.8 ∼ 10.2). The extent of maximum true lumen diameter decreased during a cardiac cycle was 49.5% ± 23.5% (range 12% ∼ 100%). The maximum motion phase of true lumen diameter was in systolic phase (5% ∼ 40% of R-R interval). Maximum and minimum intimal flap motion was at 15% and 75% of the R-R interval respectively. Intimal flap configuration had correlation with the phase of cardiac cycle. Abdominal intimal flap position and configuration varied greatly during a cardiac cycle. Retrospective ECG-gated thoracoabdominal aorta CTA can reflect the actual status of the true lumen and provide more information about true lumen collapse. This information may be helpful to diagnosis and differential diagnosis of dynamic abstraction.
Medical subject headings
- Aortic Dissection
- Angiography
- Aortic Aneurysm
- Electrocardiography
- Tomography, X-Ray Computed