Ultrasound findings after endovascular stent deployment in transplant liver hepatic artery stenosis.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 24555619.
- Also identified by DOI 10.2214/AJR.12.9612.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Endovascular stenting is a safe, effective treatment of hepatic artery stenosis after liver transplant, but no detailed evaluation has been completed of changes in ultrasound monitoring parameters after stenting. This study aims to improve poststenting surveillance by delineating the expected postoperative findings. Thirty-one stent procedures were performed at our institution for hepatic artery stenosis after liver transplant between October 2010 and October 2012. Of these, 28 (90%) were technically successful, of which 23 met the minimum follow-up time (76 days, defined by the earliest diagnosed restenosis). These patients were followed with serial ultrasound, per the following schedule: within 1 week of stenting, 3 months after stenting, 6 months after stenting, and every 6 months thereafter; additional, unscheduled examinations were frequently performed when indicated on the basis of deterioration of clinical and laboratory status. Follow-up examinations (mean, 268 days total follow-up) were compared with prestenting examinations to evaluate changes in peak systolic velocity (PSV), resistive index (RI), and tardus-parvus waveforms. Data were analyzed to determine a normal range for postprocedure values and time course of change in values. Of the 23 patients, six experienced restenosis. In all patients, mean PSV decreased by 124 cm/s, and mean RI increased by 0.13 within 48 hours after stenting. PSV differed between patency and restenosis groups only at more than 90 days after stenting (mean PSV, 234 and 400 cm/s, respectively), with PSV above 300 cm/s serving as a high-sensitivity threshold for the determination of restenosis. Prestenting RI of below 0.40 had a strong correlation with restenosis. Poststenting RI differed between patency and restenosis groups only at more than 48 hours after stenting, with RI of below 0.55 having a strong correlation with restenosis. Tardus-parvus waveform resolution was often delayed well beyond 48 hours after stenting, and time to tardus-parvus waveform resolution had no correlation with patency or restenosis. Ultrasound is convenient and useful to follow stents in hepatic artery stenosis after liver transplant. Prestenting hemodynamics can have value in predicting restenosis. Diagnosis of restenosis can be made with RI and PSV, whereas resolution time of tardus-parvus waveform is of less concern. These parameters can guide which patients require closer monitoring and aggressive treatment.
Medical subject headings
- Arterial Occlusive Diseases
- Blood Vessel Prosthesis
- Graft Occlusion, Vascular
- Liver Transplantation
- Stents