CT protocol review and optimization.
review · Level V
Where this comes from
- Record sourced from PubMed, PMID 24589402.
- Also identified by DOI 10.1016/j.jacr.2013.10.013.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To reduce the radiation dose associated with CT scans, much attention is focused on CT protocol review and improvement. In fact, annual protocol reviews will soon be required for ACR CT accreditation. A major challenge in the protocol review process is determining whether a current protocol is optimal and deciding what steps to take to improve it. In this paper, the authors describe methods for pinpointing deficiencies in CT protocols and provide a systematic approach for optimizing them. Emphasis is placed on a team approach, with a team consisting of at least one radiologist, one physicist, and one technologist. This core team completes a critical review of all aspects of a CT protocol and carefully evaluates proposed improvements. Changes to protocols are implemented only with consensus of the core team, with consideration of all aspects of the CT examination, including image quality, radiation dose, patient care and safety, and workflow.
Medical subject headings
- Practice Guidelines as Topic
- Radiation Protection
- Radiographic Image Enhancement
- Radiology
- Tomography, X-Ray Computed