Valgus subsidence of the tibial component in cementless Oxford unicompartmental knee replacement.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 24589789.
- Also identified by DOI 10.1302/0301-620X.96B3.33182 and PMC identifier 4292015.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The cementless Oxford unicompartmental knee replacement has been demonstrated to have superior fixation on radiographs and a similar early complication rate compared with the cemented version. However, a small number of cases have come to our attention where, after an apparently successful procedure, the tibial component subsides into a valgus position with an increased posterior slope, before becoming well-fixed. We present the clinical and radiological findings of these six patients and describe their natural history and the likely causes. Two underwent revision in the early post-operative period, and in four the implant stabilised and became well-fixed radiologically with a good functional outcome. This situation appears to be avoidable by minor modifications to the operative technique, and it appears that it can be treated conservatively in most patients.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Osteoarthritis, Knee
- Postoperative Complications
- Tibia
Anatomy
- knee
- tibia