Long-term results using the straight tapered femoral cementless hip stem in total hip arthroplasty: a minimum of twenty-year follow-up.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 24656056.
- Also identified by DOI 10.1016/j.arth.2014.02.015.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We report the first long-term results of a prospective cohort study after total hip arthroplasty using the cementless Bicontact hip stem. Between 1987 and 1990, 250 total hip arthroplasties in 236 patients were performed using the cementless Bicontact hip stem. The average follow-up was 22.8 years (20.4-24.8) and average age at index surgery was 58.1 years. Eighty-one patients died and 9 were lost to follow-up. We noted 11 stem revisions revealing an overall Kaplan Meier survival rate of 95.0% (CI 95%: 91.1-97.2%). The average Harris Hip Score revealed 81 points (range 24-93). The Bicontact hip stem demonstrated high survival rates despite high ages and osteopenic changes, which are equivalent to other long-term reports of cementless stem fixation.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Prosthesis
- Prosthesis Failure
Anatomy
- femur
- hip