Fixation of unstable type II clavicle fractures with distal clavicle plate and suture button.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 24667803.
- Also identified by DOI 10.1097/BOT.0000000000000081.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This article reports on a technique to treat unstable type II distal clavicle fractures using fracture-specific plates and coracoclavicular augmentation with a suture button. Six patients with clinically unstable type II distal clavicle fractures underwent treatment using the above technique. All fractures demonstrated radiographic union at 9.6 (8.4-11.6) weeks with a mean follow-up of 15.6 (12.4-22.3) months. American Shoulder and Elbow Surgeons, Penn Shoulder Score, and Single Assessment Numeric Evaluation scores were 97.97 (98.33-100), 96.4 (91-99), and 95 (90-100), respectively. One patient required implant removal. Fracture-specific plating with suture-button augmentation for type II distal clavicle fractures provides reliable rates of union without absolute requirement for implant removal.
Medical subject headings
- Bone Plates
- Clavicle
- Fracture Fixation, Internal
- Fractures, Bone
- Sutures
Anatomy
- clavicle