Fiber-optic bronchoscopy and volume-cycled mouthpiece ventilation for a patient with multiple sclerosis and ventilatory failure.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 24743461.
- Also identified by DOI 10.1097/PHM.0000000000000096.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Fiber-optic bronchoscopy supported by continuous or bilevel positive airway pressure has helped patients with hypoxemic or hypercapnic respiratory failure avoid respiratory complications. The authors describe a case of a 57-yr-old man with multiple sclerosis with a vital capacity of 250 ml (5% of predicted normal) who was using continuous noninvasive intermittent positive pressure ventilatory support when he underwent bronchoscopy while receiving continuous noninvasive intermittent positive pressure ventilatory support via a 15-mm angled mouthpiece interface. He was switched from a nasal to a 15-mm angled mouthpiece interface for continuous noninvasive intermittent positive pressure ventilatory support for the procedure. Simple mouthpieces may be useful alternatives to other facial interfaces for ventilatory support during bronchoscopy because of patient comfort and operator convenience.
Medical subject headings
- Bronchoscopy
- Continuous Positive Airway Pressure
- Intermittent Positive-Pressure Breathing
- Multiple Sclerosis
- Respiratory Insufficiency