Application of a vibrating device for the prevention of flexion contracture after total knee arthroplasty.

Manó, Sándor; Pálinkás, Judit; Szabó, János; Nagy, Judit T; Bakó, Katalin; Csernátony, Zoltán · Eur J Orthop Surg Traumatol · 2015

rct · Level II

Where this comes from

Abstract

Our research team developed a new, heel support-based static and vibrating complementary treatment method for the prevention of flexion contractures often arising after total knee arthroplasty. We examined the efficiency of the method performing a randomized clinical trial with 144 patients undergoing total knee replacement. Seventy-nine patients were treated for 1 week with a generally used continuous passive motion (CPM) device complemented with our new method, which was based on the application of a static and an alternating heel support. The 65 patients in the control group were treated with only a CPM device as in usual clinical practice. The femoro-tibial angle was measured immediately following surgery, and after 1 week of treatment. At the end of the 1 week treatment, the target extension angle (0° ± 5°) was achieved by significantly more patients with the new combined method. This way the elevated heel rest and the vibrating device proved to be a good adjunct treatment along with the CPM used in routine clinical practice in the first place for the prevention of flexion contractures.

Medical subject headings

Anatomy