Evaluation of anterior cervical reconstruction with titanium mesh cages versus nano-hydroxyapatite/polyamide66 cages after 1- or 2-level corpectomy for multilevel cervical spondylotic myelopathy: a retrospective study of 117 patients.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 24789144.
- Also identified by DOI 10.1371/journal.pone.0096265 and PMC identifier 4008500.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
To retrospectively compare the efficacy of the titanium mesh cage (TMC) and the nano-hydroxyapatite/polyamide66 cage (n-HA/PA66 cage) for 1- or 2-level anterior cervical corpectomy and fusion (ACCF) to treat multilevel cervical spondylotic myelopathy (MCSM). A total of 117 consecutive patients with MCSM who underwent 1- or 2-level ACCF using a TMC or an n-HA/PA66 cage were studied retrospectively at a mean follow-up of 45.28 ± 12.83 months. The patients were divided into four groups according to the level of corpectomy (1- or 2-level corpectomy) and cage type used (TMC or n-HA/PA66 cage). Clinical and radiological parameters were used to evaluate outcomes. At the one-year follow-up, the fusion rate in the n-HA/PA66 group was higher, albeit non-significantly, than that in the TMC group for both 1- and 2-level ACCF, but the fusion rates of the procedures were almost equal at the final follow-up. The incidence of cage subsidence at the final follow-up was significantly higher in the TMC group than in the n-HA/PA66 group for the 1-level ACCF (24% vs. 4%, p = 0.01), and the difference was greater for the 2-level ACCF between the TMC group and the n-HA/PA66 group (38% vs. 5%, p = 0.01). Meanwhile, a much greater loss of fused height was observed in the TMC group compared with the n-HA/PA66 group for both the 1- and 2-level ACCF. All four groups demonstrated increases in C2-C7 Cobb angle and JOA scores and decreases in VAS at the final follow-up compared with preoperative values. The lower incidence of cage subsidence, better maintenance of the height of the fused segment and similar excellent bony fusion indicate that the n-HA/PA66 cage may be a superior alternative to the TMC for cervical reconstruction after cervical corpectomy, in particular for 2-level ACCF.
Medical subject headings
- Cervical Vertebrae
- Nanocomposites
- Plastic Surgery Procedures
- Spinal Cord Diseases
- Spondylosis
- Titanium