A randomized comparison of platinum chromium-based everolimus-eluting stents versus cobalt chromium-based Zotarolimus-Eluting stents in all-comers receiving percutaneous coronary intervention: HOST-ASSURE (harmonizing optimal strategy for treatment of coronary artery stenosis-safety & effectiveness of drug-eluting stents & anti-platelet regimen), a randomized, controlled, noninferiority trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 24814486.
- Also identified by DOI 10.1016/j.jacc.2014.04.013.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
This study sought to test whether the newly developed platinum chromium (PtCr)-based everolimus-eluting stent (EES) is noninferior to the cobalt chromium (CoCr)-based zotarolimus-eluting stent (ZES) in all-comers receiving percutaneous coronary intervention (PCI). PtCr provides improved radial strength, conformability, and visibility compared with the CoCr alloy, but PtCr-based stents have not been tested in a wide range of patients receiving PCI. Also, recent case series have raised the issue of longitudinal stent deformation (LSD) with newer drug-eluting stents. We randomly assigned 3,755 all-comers receiving PCI to PtCr-EES or CoCr-ZES. The primary outcome was target lesion failure (TLF) at 1-year post-PCI, defined as the composite of cardiac death, nonfatal target vessel-related myocardial infarction, and ischemia-driven target lesion revascularization. Post-hoc angiographic analysis was performed to qualitatively and quantitatively analyze LSD. At 1 year, TLF occurred in 2.9% and 2.9% of the population in the PtCr-EES and CoCr-ZES groups, respectively (superiority p = 0.98, noninferiority p = 0.0247). There were no significant differences in the individual components of TLF as well as the patient-oriented clinical outcome. Of 5,010 stents analyzed, LSD occurred in 0.2% and 0% in the PtCr-EES and CoCr-ZES groups, respectively (p = 0.104). There was no significant difference in post-deployment stent length ratio between the 2 stents (p = 0.352). At 1 year, PtCr-EES was noninferior to CoCr-ZES in all-comers receiving PCI. Although LSD was observed only in PtCr-EES, both the stent length ratio and the frequency of LSD were not significantly different between the 2 stent types, and PtCr-EES was not associated with adverse clinical outcomes. (Harmonizing Optimal Strategy for Treatment of Coronary Artery Stenosis-SAfety & EffectiveneSS of Drug-ElUting Stents & Anti-platelet REgimen [HOST-ASSURE]; NCT01267734).
Medical subject headings
- Coronary Stenosis
- Drug-Eluting Stents
- Immunosuppressive Agents
- Percutaneous Coronary Intervention
- Platelet Aggregation Inhibitors
- Sirolimus