Results of a systematic approach to exchange nailing for the treatment of aseptic tibial nonunions.

Swanson, Eli A; Garrard, Eli C; OʼConnor, Daniel P; Brinker, Mark R · J Orthop Trauma · 2015

retrospective_cohort · Level III

Where this comes from

Abstract

The purpose of this study was to evaluate the effectiveness of a systematic approach to exchange nailing for the treatment of aseptic tibial nonunion. Retrospective cohort. Tertiary referral center. Forty-six aseptic tibial nonunion sites in 40 patients (2 bilateral and 4 segmental) who presented with an intramedullary nail on an average of 16 months after the initial treatment were presented in this study. Insertion of an exchange nail of at least >2-mm diameter than the prior nail using a different manufacturer's nail, static interlocking, partial fibulectomy in a select group of patients, and correction of underlying metabolic and endocrine abnormalities. Union rate, time to union. Forty-five of 46 tibial nonunion sites (98%) healed at an average of 4.8 months. Patient selection criteria and a systematic approach to exchange nailing for tibial nonunion is highly successful. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Medical subject headings

Anatomy