I.v. contrast administration with dual source 128-MDCT: a randomized controlled study comparing 18-gauge nonfenestrated and 20-gauge fenestrated catheters for catheter placement success, infusion rate, image quality, and complications.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 24848812.
- Also identified by DOI 10.2214/AJR.13.11730.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to compare the performance of a 20-gauge fenestrated catheter with an 18-gauge nonfenestrated catheter for i.v. contrast infusion during MDCT. Two hundred five adult outpatients imaged on a dual-source 128-MDCT scanner with arterial phase body CT (flow rates, 5.0-7.5 mL/s) were randomized to either an 18-gauge nonfenestrated or 20-gauge fenestrated catheter. After randomization, any 18-gauge nonfenestrated subjects whose veins were deemed insufficient for that catheter gauge were assigned to a third cohort for placement of a 20-gauge fenestrated catheter. Catheter placement success, infusion rate, contrast volume, maximum pressure, complications, and aortic enhancement levels were recorded. Catheters were placed on the first attempt in 97% (100/103) for 18-gauge nonfenestrated and 94% (96/102) for 20-gauge fenestrated placements and in two or fewer attempts in 99% of both groups. Mean infusion rates (5.74 mL/s for 18-gauge nonfenestrated and 5.58 mL/s for 20-gauge fenestrated placements) and aortic enhancement levels were not significantly different. Maximum pressure was higher with 20-gauge fenestrated catheters (mean ± SD, 230.5 ± 27.6 pounds per square inch [psi]) than 18-gauge nonfenestrated catheters (mean ± SD 215.6 ± 32.8 psi) (p = 0.002). One subject with an 18-gauge nonfenestrated catheter had a high-pressure alarm. In the third cohort, a 20-gauge fenestrated catheter was successfully placed in two or fewer attempts in 85% (28/33), with one minor extravasation attributed to vein insufficiency. A 20-gauge fenestrated catheter performs similarly to an 18-gauge nonfenestrated catheter with respect to i.v. contrast infusion rates and aortic enhancement levels and can be placed in most subjects whose veins are deemed insufficient for an 18-gauge catheter.
Medical subject headings
- Central Venous Catheters
- Contrast Media
- Foreign-Body Migration
- Infusions, Intravenous
- Multidetector Computed Tomography
- Radiography, Interventional