Late aneurysm rupture after delayed secondary open conversion with partial explantation for failed endovascular repair.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 24865785.
- Also identified by DOI 10.1016/j.jvs.2014.04.054.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
A delayed secondary open conversion (SOC) after endovascular aneurysm repair may be necessary due to a failing graft. Many surgical techniques can be performed, and one such approach is partial explantation of the graft with resuturing of a new graft to the retained components of the endograft. No guidelines exist with regards to the follow-up of retained endovascular components after a delayed SOC. The theoretical risk of endoleaks remains with retained components, and this case demonstrates the development of a type Ib endoleak after SOC leading to free flow of blood into a partially resected aneurysm sac and causing a symptomatic aneurysm rupture.
Medical subject headings
- Aortic Aneurysm, Abdominal
- Aortic Rupture
- Blood Vessel Prosthesis
- Blood Vessel Prosthesis Implantation
- Device Removal
- Endoleak
- Endovascular Procedures
- Stents