Effect of cricoid pressure on placement of the I-gel™ : a randomised study.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 24866121.
- Also identified by DOI 10.1111/anae.12731.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We studied 40 adult patients to see if cricoid pressure affected placement of the I-gel(™). In a randomised crossover design, the i-gel was placed with and without cricoid pressure, and we compared the success rate of adequate ventilation through the i-gel, time to placement and the rate of optimal position of the device between the two circumstances. Cricoid pressure significantly decreased the success rate of adequate ventilation through the i-gel (40 vs 34 patients) (p = 0.041, 95% CI for difference 4-26%), and significantly decreased the rate of the optimal position (39 vs 17 patients) (p < 0.001). The time to achieve adequate ventilation was significantly longer (p < 0.001) with cricoid pressure than without (median difference 8 s; 95% CI for median difference 3-12 s). Cricoid pressure significantly decreases the success rate of ventilation through the i-gel, but the success rate of ventilation through the i-gel is reasonably high.
Medical subject headings
- Cricoid Cartilage
- Elastomers
- Laryngeal Masks