Proximal thoracic endograft displacement rescued by balloon-assisted pull-back, external shunting, and in situ fenestration of the left carotid artery.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 25080881.
- Also identified by DOI 10.1016/j.jvs.2014.05.043.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Proximal displacement of thoracic aortic endografts is a catastrophic adverse event, which rarely occurs but is associated with extremely high morbidity and mortality. We describe herein the case of a patient with accidental proximal displacement of a thoracic endograft with occlusion of all supra-aortic branches, successfully rescued by the combination of three advanced endovascular techniques: (1) aggressive pull-back maneuver with a compliant balloon; (2) establishment of an arterio-arterial temporary shunt to the occluded carotid artery over sheaths; and (3) in-situ fenestration of the occluded carotid artery.
Medical subject headings
- Aortic Dissection
- Angioplasty, Balloon
- Aortic Aneurysm, Thoracic
- Blood Vessel Prosthesis
- Blood Vessel Prosthesis Implantation
- Carotid Artery, Common
- Carotid Stenosis
- Endovascular Procedures
- Foreign-Body Migration
- Stents