Bone-prosthesis composite with rotating hinged-knee prosthesis in limb salvage surgery for high-grade sarcoma around the knee.

Wang, Chien-Shun; Wu, Po-Kuei; Chen, Cheng-Fong; Chen, Wei-Ming; Liu, Chien-Lin; Chen, Tain-Hsiung · J Arthroplasty · 2015

retrospective_cohort · Level III

Where this comes from

Abstract

Bone prosthesis composite (BPC) had been widely-used in reconstruction after wide excision of malignant tumors around the knee. However, implant selection for BPC remains a dilemma. Forty-one patients with high-grade malignant bone tumors around the knee who underwent excision and reconstruction with BPC and rotating hinged knee (RHK) prosthesis were included. The mean follow-up time was 54 months (range, 31-78 months). The average Musculoskeletal Tumor Society Rating score was 93.4% (range, 73-100%). The mean range of motion was 125°. Complications included 2 local recurrences, 2 nonunions, and 1 peri-prosthetic fracture. The reconstruction with BPC using the RHK prosthesis provided consistently good functional results with a low complication rate. The RHK prosthesis is a promising choice for BPC reconstruction.