Mechanical aortic valve-on-valve replacement in previous Bentall procedure: an alternate technique.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 25193228.
- Also identified by DOI 10.1016/j.athoracsur.2014.02.083.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Acute aortic valve regurgitation due to thrombosed prosthetic valve can present as a surgical emergency. This article reports a successful and unusual management of a young pregnant female patient who presented with acute aortic valve regurgitation due to a thrombosed mechanical aortic valve. As the patient had previous multiple cardiac surgeries, the options were limited for repeat aortic valve or aortic root replacement. The patient had caesarean section followed by implantation of a mechanical valve-on-valve in a previously placed composite valved conduit. This technique may be useful for reoperative valve replacement in the setting of a prior mechanical Bentall patient.
Medical subject headings
- Aortic Valve
- Aortic Valve Insufficiency
- Heart Valve Prosthesis
- Heart Valve Prosthesis Implantation
- Pregnancy Complications, Cardiovascular
- Thrombosis