A radiographic comparison of femoral offset after cemented and cementless total hip arthroplasty.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 25198306.
- Also identified by DOI 10.5301/hipint.5000160.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Restoring femoral offset during total hip arthroplasty is important. Femoral offset and leg lengths are inextricably linked by the caput-collum-diaphysis (CCD) angle of the implant being used. We investigate the restoration of offset and leg lengths using the radiographs of a consecutive series of patients following implantation with either a high CCD angled cementless, or an anatomical CCD angled cemented femoral component. Although our data suggests that we are able to restore femoral offset and leg lengths using either device, we recommend additional caution when using non-anatomical high CCD angled implants.
Medical subject headings
- Arthroplasty, Replacement, Hip
- Hip Joint
- Hip Prosthesis
Anatomy
- femur
- hip