Foreign body reaction after PLC reconstruction caused by a broken PLLA screw.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 25437089.
- Also identified by DOI 10.3928/01477447-20141124-91.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Foreign body reactions may occur in patients who receive bioabsorbable implants during orthopedic surgery for fractures and ligament repair. The authors describe a 34-year-old man who presented with a palpable tender mass on the lateral aspect of the left knee of 1 month's duration. He underwent posterior cruciate ligament and posterolateral corner reconstruction 3 years earlier. Physical examination showed a 1×1-cm soft, nontender mass without localized warmth on the lateral epicondyle of the distal femur. Magnetic resonance imaging showed a broken screw fragment surrounded by a cyst-like mass. Under general anesthesia, the surgeon excised the screw fragment and the fibrotic mass, enclosing it in the subcutaneous tissue at the lateral epicondyle, the site at which a poly-L-lactic acid bioabsorbable screw had been inserted to fix the graft for posterolateral corner reconstruction. Histologic evaluation showed a foreign body reaction to the degraded screw particles. To the authors' knowledge, this report is the first description of a patient presenting with a delayed foreign body reaction to a broken poly-L-lactic acid bioabsorbable screw at the lateral femoral epicondyle after posterolateral corner reconstruction. Because delayed foreign body reactions can occur at any site of poly-L-lactic acid bioabsorbable screw insertion, care should be taken to avoid screw protrusion during ligament reconstruction because it can lead to screw breakage and delayed foreign body reaction.
Medical subject headings
- Bone Screws
- Foreign-Body Reaction
- Posterior Cruciate Ligament