Rectal toxicity after intensity modulated radiotherapy for prostate cancer: which rectal dose volume constraints should we use?
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 25441610.
- Also identified by DOI 10.1016/j.radonc.2014.10.014.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To define rectal dose volume constraints (DVC) to prevent ⩾grade2 late rectal toxicity (LRT) after intensity modulated radiotherapy (IMRT) for prostate cancer (PC). Six hundred thirty-seven PC patients were treated with primary (prostate median dose: 78Gy) or postoperative (prostatic bed median dose: 74Gy (adjuvant)-76Gy (salvage)) IMRTwhile restricting the rectal dose to 76Gy, 72Gy and 74Gy respectively. The impact of patient characteristics and rectal volume parameters on ⩾grade2 LRT was determined. DVC were defined to estimate the 5% and 10% risk of developing ⩾grade2 LRT. The 5-year probability of being free from ⩾grade2 LRT, non-rectal blood loss and persisting symptoms is 88.8% (95% CI: 85.8-91.1%), 93.4% (95% CI: 91.0-95.1%) and 94.3% (95% CI: 92.0-95.9%) respectively. There was no correlation with patient characteristics. All volume parameters, except rectal volume receiving ⩾70Gy (R70), were significantly correlated with ⩾grade2 LRT. To avoid 10% and 5% risk of ⩾grade2 LRT following DVC were derived: R40, R50, R60 and R65 <64-35%, 52-22%, 38-14% and 5% respectively. Applying existing rectal volume constraints resulted in a 5-year estimated risk of developing late ⩾grade2 LRT of 11.2%. New rectal DVC for primary and postoperative IMRT planning of PC patients are proposed. A prospective evaluation is needed.
Medical subject headings
- Prostatic Neoplasms
- Radiation Injuries
- Radiotherapy, Intensity-Modulated
- Rectum