Concern that laryngoscopy and intubation might create or exacerbate a spinal cord injury has generated extensive research into cervical spinal movement during laryngoscopy. We performed a randomised trial on six cadavers, using three different laryngoscopes, before and after creating a type-2 odontoid peg fracture. Our primary outcome measure was the change in the space available for the spinal cord at the C1/2 segment measured by cinefluoroscopy. Tracheal intubation was performed using a minimal view of the glottis, a bougie, and manual in-line stabilisation. In a cadaveric model of type-2 odontoid fracture, the space available for the cord was preserved in maximum flexion and extension, and changed little on laryngoscopy and intubation.