Medial femoral condyle fracture as an intraoperative complication of Oxford unicompartmental knee replacement.

Ten Brinke, Bart; de Haan, Laurens J; Koenraadt, Koen L M; van Geenen, Rutger C I · Knee Surg Sports Traumatol Arthrosc · 2016

case_report · Level V

Where this comes from

Abstract

Oxford unicompartmental knee replacement (OUKR) is associated with a low perioperative complication rate. This case report describes a periprosthetic fracture of the medial femoral condyle that occurred during an OUKR. The patient was treated with a non-weight-bearing long leg cast for 6 weeks. Afterwards, the fracture had healed, and 3 months postoperatively, there was a full range of motion. Factors leading to this complication could be the impaction force or direction, or a diminished load resistance of the distal femur. Minimally displaced coronal periprosthetic fractures after OUKR can be managed conservatively without residual functional impairment. Case report, Level IV.

Medical subject headings

Anatomy