Complete rupture of the popliteal artery complicating high tibial osteotomy.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 25561756.
- Also identified by DOI 10.1016/j.jor.2014.08.002 and PMC identifier 4281602.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We present two cases of high tibial osteotomies performed at our institution. Both cases were complicated with the immediate postoperative occurrence of an ischaemic syndrome of the lower leg. Urgent diagnostics revealed a complete rupture of the popliteal artery that required re-operation and a vascular repair. Although neurovascular complications during high tibial osteotomies are rare the awareness of this potentially catastrophic complication should be present when performing this common procedure. All precautions to minimize the harm to the neurovascular bundle should be put into practice. A summary of the surgical precautions is presented and discussed in this paper.
Anatomy
- tibia