Prospective multicenter study of a synthetic bioabsorbable anal fistula plug to treat cryptoglandular transsphincteric anal fistulas.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 25664714.
- Also identified by DOI 10.1097/DCR.0000000000000288.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Although interest in sphincter-sparing treatments for anal fistulas is increasing, few large prospective studies of these approaches have been conducted. The study assessed outcomes after implantation of a synthetic bioabsorbable anal fistula plug. A prospective, multicenter investigation was performed. The study was conducted at 11 colon and rectal centers. Ninety-three patients (71 men; mean age, 47 years) with complex cryptoglandular transsphincteric anal fistulas were enrolled. Exclusion criteria included Crohn's disease, an active infection, a multitract fistula, and an immunocompromised status. Draining setons were used at the surgeon's discretion. Patients had follow-up evaluations at 1, 3, 6, and 12 months postoperatively. The primary end point was healing of the fistula, defined as drainage cessation plus closure of the external opening, at 6 and 12 months. Secondary end points were fecal continence, duration of drainage from the fistula, pain, and adverse events during follow-up. Thirteen patients were lost to follow-up and 21 were withdrawn, primarily to undergo an alternative treatment. The fistula healing rates at 6 and 12 months were 41% (95% CI, 30%-52%; total n = 74) and 49% (95% CI, 38%-61%; total n = 73). Half the patients in whom a previous treatment failed had healing. By 6 months, the mean Wexner score had improved significantly (p = 0.0003). By 12 months, 93% of patients had no or minimal pain. Adverse events included 11 infections/abscesses, 2 new fistulas, and 8 total and 5 partial plug extrusions. The fistula healed in 3 patients with a partial extrusion. The study was nonrandomized and had relatively high rates of loss to follow-up. Implantation of a synthetic bioabsorbable fistula plug is a reasonably efficacious treatment for complex transsphincteric anal fistulas, especially given the simplicity and low morbidity of the procedure.
Medical subject headings
- Abdominal Wound Closure Techniques
- Absorbable Implants
- Digestive System Surgical Procedures
- Drainage
- Postoperative Complications
- Rectal Fistula
- Surgical Instruments