Arthroscopy of the nondistractable hip: a novel extracapsular approach.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 25685682.
- Also identified by DOI 10.1016/j.eats.2014.09.003 and PMC identifier 4314553.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Adequate traction to achieve hip joint distraction is essential for avoiding iatrogenic injury to the joint during hip arthroscopy. An inability to distract the joint is a relative contraindication for hip arthroscopy. This report describes a novel technique involving an extracapsular approach to gain safe access to a hip joint that fails a trial of traction during positioning for hip arthroscopy. The anterolateral portal is established under fluoroscopic guidance. The arthroscope is positioned on the lateral rim of the acetabulum. A shaver, introduced through a modified anterior portal, is used to facilitate capsular exposure. An arthroscopic capsular incision is made proximal to the lateral acetabular rim and extended anteriorly with a radiofrequency probe. Osteoplasty of the anterolateral acetabular rim is carried out with a burr while protecting the labrum. Distraction of the hip is then possible, allowing safe central-compartment access and subsequent chondrolabral procedures.
Anatomy
- hip