Impact of Hamstring Graft Diameter on Tendon Strength: A Biomechanical Study.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 25703286.
- Also identified by DOI 10.1016/j.arthro.2014.12.023.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to compare the tensile strength of hamstring grafts of varying combined pull-through diameters within the clinically relevant range of 6 to 9 mm. We tested 44 non-irradiated allograft hamstring grafts (11 per group). Combined looped semitendinosus and gracilis grafts were allocated to the 6-, 7-, 8-, or 9-mm group based on the smallest-diameter lumen that the graft could be "pulled through" using a surgical sizing instrument. Testing was performed on an Instron materials testing machine (Instron, Norwood, MA). Samples were secured with cryoclamps, prestressed, and pulled to failure at a rate of 10% gauge length per second. The mean load to failure was 2,359 ± 474 N, 3,263 ± 677 N, 3,908 ± 556 N, and 4,360 ± 606 N for the 6-, 7-, 8-, and 9-mm grafts, respectively. Minimum failure loads were as low as 1,567 N, 2,288 N, 2,874 N, and 3,720 N for each group, respectively. There were statistically significant differences between the 6- and 7-mm, 6- and 8-mm, 6- and 9-mm, and 7- and 9-mm groups (P = .01). Statistically different increasing tensile strength was seen as graft diameter increased. Significant variability exists in the strength of multi-stranded hamstring allografts within the diameter range of 6 to 9 mm that often falls well below the commonly accepted value of 4,000 N for a hamstring graft. Recent evidence suggests a higher early failure rate of hamstring autografts in subsets of patients with graft diameters of 8 mm or less. This study may increase awareness that hamstring grafts may not be nearly as strong as previously appreciated and that increasing tendon diameters by 1 to 2 mm may dramatically affect graft strength. These data may be helpful in preoperative discussions regarding variable hamstring size, strength, and potential intraoperative augmentation options.
Medical subject headings
- Anterior Cruciate Ligament
- Anterior Cruciate Ligament Reconstruction
- Tendons