Atomic-accuracy models from 4.5-Å cryo-electron microscopy data with density-guided iterative local refinement.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 25707030.
- Also identified by DOI 10.1038/nmeth.3286 and PMC identifier 4382417.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We describe a general approach for refining protein structure models on the basis of cryo-electron microscopy maps with near-atomic resolution. The method integrates Monte Carlo sampling with local density-guided optimization, Rosetta all-atom refinement and real-space B-factor fitting. In tests on experimental maps of three different systems with 4.5-Å resolution or better, the method consistently produced models with atomic-level accuracy largely independently of starting-model quality, and it outperformed the molecular dynamics-based MDFF method. Cross-validated model quality statistics correlated with model accuracy over the three test systems.
Medical subject headings
- Chemistry, Physical
- Cryoelectron Microscopy
- Models, Molecular
- Proteins