Variation in CT pediatric head examination radiation dose: results from a national survey.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 25714315.
- Also identified by DOI 10.2214/AJR.14.12997.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
OBJECTIVE. The purpose of this article is to examine the variation in radiation dose, CT dose index volume (CTDIvol), and dose-length product (DLP) for pediatric head CT examinations as a function of hospital characteristics across the United States. MATERIALS AND METHODS. A survey inquiring about hospital information, CT scanners, pediatric head examination protocol, CTDIvol, and DLP was mailed to a representative sample of U.S. hospitals. Follow-up mailings were sent to nonrespondents. Descriptive characteristics of respondents and nonrespondents were compared using design-based Pearson chi-square tests. Dose estimates were compared across hospital characteristics using Bonferroni-adjusted Wald test. Hospital-level factors associated with dose estimates were evaluated using multiple linear regressions and modified Poisson regression models. RESULTS. Surveys were sent out to 751 hospitals; 292 responded to the survey, of which 253 were eligible (35.5% response rate, calculated as number of hospitals who completed surveys [n = 253] divided by sum of number who were eligible and initially consented [n = 712] plus estimated number who were eligible among those who refused [n = 1]). Most respondents reported using MDCT scanners (99.2%) and having a dedicated pediatric head CT protocol (93%). Estimated mean reported CTDIvol values were 27.3 mGy (95% CI, 24.4-30.1 mGy), and DLP values were 390.9 mGy × cm (95% CI, 346.6-435.1 mGy × cm). These values did not vary significantly by region, trauma level, teaching status, CT accreditation, number of CT scanners, or report of a dedicated pediatric CT protocol. However, estimated CTDIvol reported by children's hospitals was 19% lower than that reported by general hospitals (p < 0.01). CONCLUSION. Most hospitals (82%) report doses that meet American College of Radiology accreditation levels. However, [corrected] the mean CTDI(vol) at children's hospitals was approximately 7 mGy (21%, adjusted for covariates), lower than that at nonchildren's hospitals.
Medical subject headings
- Head
- Practice Patterns, Physicians'
- Radiation Dosage
- Tomography, X-Ray Computed