Biomechanical evaluation of two innovative locking implants for comminuted olecranon fractures under high-cycle loading conditions.
biomechanical · Level V
Where this comes from
- Record sourced from PubMed, PMID 25771445.
- Also identified by DOI 10.1016/j.injury.2015.02.010.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The relatively high complication rate after fixation of olecranon fractures has led to an increasing application of anatomically pre-contoured locking plate systems. The purpose of the present study was to conduct a biomechanical comparison of olecranon osteosyntheses by applying the Olecranon VA-LCP and the 3.5mm LCP Hook Plate (LCP, locking compression plate) to an unstable fracture model under high-cycle loading conditions. After creating an unstable fracture (Schatzker type B), osteosynthesis was performed on eight pairs of fresh-frozen cadaveric ulnae by application of either the Olecranon VA-LCP (Synthes, Solothurn, Switzerland) or the 3.5mm LCP Hook Plate (Synthes, Solothurn, Switzerland). Loading (50,000 alternating loads, cyclic and sinusoidal 10-300 N) was conducted by application of tensile load with the elbow in 90° flexion to simulate the tensile strength of the triceps brachii. For statistical analysis, angular displacement in the region of the humeral trochlea was taken as a measure of olecranon dislocation. In Group 1 (Olecranon VA-LCP), a median angular displacement of 0.36° (minimum 0.10°; maximum 0.80°) was observed after 500 alternating loads. In Group 2 (3.5-mm LCP Hook Plate), the medial displacement was 0.80° (minimum 0.13°; maximum 2.72°). The difference was nonsignificant (p = 0.128). The mean value for angular displacement in Group 1 after 50,000 cycles was 0.80° (minimum 0.31°; maximum 1.99°), whereas in Group 2 a mean angular displacement of 2.02° (minimum 0.71°; maximum 6.40°) was recorded. The difference was statistically significant (p = 0.017). In Group 2, implant failure in the form of proximal plate pullout occurred in one construct after 756 cycles. A significantly higher biomechanical stability can be achieved in the fixation of unstable olecranon fractures by application of the Olecranon VA-LCP rather than the 3.5mm LCP Hook Plate.
Medical subject headings
- Bone Plates
- Fracture Fixation, Internal
- Fracture Fixation, Intramedullary
- Fractures, Comminuted
- Olecranon Process
- Ulna Fractures