Radioactive seed localization versus wire localization for lumpectomies: a comparison of outcomes.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 25794081.
- Also identified by DOI 10.2214/AJR.14.12743.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to compare outcomes of radioactive seed localization (RSL) versus wire localization using surgical margin size, reexcision and reoperation rates, specimen size, radiology resource utilization, and cosmesis as measures. Patients who underwent RSL before segmental mastectomy from April 1, 2011, to March 1, 2012, for biopsy-proven cancer were selected. Each was matched using tumor size, type, and surgeon to a wire localization control case, resulting in 232 cases. Width of the closest surgical margin, reexcision rate, and reoperation rate were compared as were the ratios of tumor volume to initial surgical specimen volume and tumor volume to all surgically excised volume (including reexcisions and reoperations). Cosmetic outcome was analyzed by comparison of Harvard scores and specimen volume with breast volume. Radiology resource utilization was compared before and after RSL implementation. No significant differences between methods were found in closest surgical margin (RSL mean, 0.45 cm; wire localization mean, 0.45 cm; p=0.972), reexcision rate (RSL mean, 21.1%; wire localization mean, 26.3%; p=0.360), reoperation rate (RSL, 11.4%; wire localization, 12.7%; p=0.841), ratio of the tumor volume to initial surgical specimen volume (RSL mean, 0.027; wire localization mean, 0.028; p=0.886), ratio of the tumor volume to total volume resected (RSL mean, 0.024; wire localization mean, 0.024; p=0.997), or in clinical or computed cosmesis scores (clinical p=0.5; calculated p=0.060). There was a 34% increase in scheduled biopsy slot utilization, 50% savings in time spent scheduling, and a 4.1-day average decrease in biopsy wait time after RSL institution. RSL is an acceptable alternative to wire localization and offers significant improvements in workflow.
Medical subject headings
- Breast Neoplasms
- Fiducial Markers
- Iodine Radioisotopes
- Mastectomy, Segmental