Radiological and Functional Outcomes in Computer Assisted Total Knee Arthroplasty Between Consultants and Trainees - A Prospective Randomized Controlled Trial.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 25820119.
- Also identified by DOI 10.1016/j.arth.2015.03.007.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Computer Aided Surgery has consistently shown superior alignment of components when compared to non-navigated jig based techniques. The aim of this study is to assess the mid-term clinical outcome of TKA performed by a consultant orthopedic surgeon, compared to trainee surgeons. Ninety-two patients were matched and randomly allocated to have CAS surgery performed by either a consultant or trainee and followed up prospectively for 5-years. Knee society scores, mechanical axis, tourniquet time and blood loss data were collected. Our study demonstrated that trainees were able to achieve equal coronal alignment (P=0.15), blood loss (P=0.45) and functional scores (P=0.15). The Consultant group had a significantly (P<0.001) shorter tourniquet time. We confirm that CAS can assist less experienced surgeons to reliably achieve good mid-term outcomes in TKA.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Joint Diseases
- Knee Joint
- Surgery, Computer-Assisted
Anatomy
- knee