Resolution of heart block after surgical correction of failed transcatheter aortic valve implantation.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 25841831.
- Also identified by DOI 10.1016/j.athoracsur.2014.06.102.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Surgical aortic valve replacement is the gold standard therapy for severe aortic stenosis but transcatheter aortic valve implantation (TAVI) is increasingly employed in "high-risk" patients. Atrioventricular block and aortic regurgitation are frequent complications of nitinol-based stented valves. We report a case of successful, but complex reoperative surgery 13 days after failed TAVI with iatrogenic aortic and mitral regurgitation and new-onset heart block. Removal of a CoreValve prosthesis (Medtronic Inc, Minneapolis, MN) with standard aortic valve replacement resulted in restoration of sinus rhythm and valvular competencies.
Medical subject headings
- Aortic Valve Insufficiency
- Atrioventricular Block
- Iatrogenic Disease
- Mitral Valve Insufficiency
- Transcatheter Aortic Valve Replacement