Dominant hand operating probe vs needle: a comparison study of ultrasound-guided needle placement in phantom models.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 25846452.
- Also identified by DOI 10.1111/anae.13070.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
We conducted a replicated crossover design study to assess if using one's dominant hand for operating a probe vs directing a needle would affect the time taken, the number of needle passes and the accuracy of an ultrasound-guided procedure in phantom models. Twenty ultrasound-novice participants completed the task 10 times for each hand arrangement (alternating between attempts). The time taken and number of needle passes required for both dominant hand-probe and hand-needle decreased over time (p = 0.001). Dominant hand-needle had a lower mean time used (p = 0.001) and fewer needle passes (p = 0.02) compared with hand-probe. Sixty-five per cent of participants preferred using their dominant hand to direct the needle. When learning ultrasound-guided needle procedures on phantom models, use of the dominant hand to operate the needle is associated with a shorter procedure time and fewer needle passes.
Medical subject headings
- Clinical Competence
- Functional Laterality
- Ultrasonography, Interventional