Live-Cell STED Microscopy with Genetically Encoded Biosensor.
basic_science · Level V
Where this comes from
- Record sourced from PubMed, PMID 25871892.
- Also identified by DOI 10.1021/nl504710z.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Of the various super-resolution techniques, stimulated emission depletion (STED) microscopy achieves the best temporal resolution at high spatial resolution, enabling live-cell imaging beyond the diffraction limit. However, STED and most other super-resolution imaging methods utilize a particular type of information extractable from the raw data, namely the positions of fluorophores. To expand on the use of super-resolution techniques, we report here the live-cell STED microscopy of a dynamic biosensor. Using the fluorescent H2O2 sensor HyPer2 for subdiffraction imaging, we were able not only to image filaments with superior resolution by localizing emission but also to trace H2O2 produced within living cell by monitoring brightness of the probe. STED microscopy of HyPer2 demonstrates potential utility of FP-based biosensors for super-resolution experiments in situ and in vivo.