Keratometric index obtained by Fourier-domain optical coherence tomography.
cross_sectional · Level IV
Where this comes from
- Record sourced from PubMed, PMID 25886489.
- Also identified by DOI 10.1371/journal.pone.0122441 and PMC identifier 4401696.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
To determine the keratometric indices calculated based on parameters obtained by Fourier-domain optical coherence tomography (FD-OCT). The ratio of anterior corneal curvature to posterior corneal curvature (Ratio) and keratometric index (N) were calculated within central 3 mm zone with the RTVue FD-OCT (RTVue, Optovue, Inc.) in 186 untreated eyes, 60 post-LASIK/PRK eyes, and 39 keratoconus eyes. The total corneal powers were calculated using different keratometric indices: Kcal based on the mean calculated keratometric index, K1.3315 calculated by the keratometric index of 1.3315, and K1.3375 calculated by the keratometric index of 1.3375. In addition, the total corneal powers based on Gaussian optics formula (Kactual) were calculated. The means for Ratio in untreated controls, post-LASIK/PRK group and keratoconus group were 1.176 ± 0.022 (95% confidence interval (CI), 1.172-1.179), 1.314 ± 0.042 (95%CI, 1.303-1.325) and 1.229 ± 0.118 (95%CI, 1.191-1.267), respectively. And the mean calculated keratometric index in untreated controls, post-LASIK/PRK group and keratoconus group were 1.3299 ± 0.00085 (95%CI, 1.3272-1.3308), 1.3242 ± 0.00171 (95%CI, 1.3238-1.3246) and 1.3277 ± 0.0046 (95%CI, 1.3263-1.3292), respectively. All the parameters were normally distributed. The differences between Kcal and Kactual, K1.3315 and Kactual, and K1.3375 and Kactual were 0.00 ± 0.11 D, 0.21 ± 0.11 D and 0.99 ± 0.12 D, respectively, in untreated controls; -0.01 ± 0.20 D, 0.85 ± 0.18 D and 1.56 ± 0.16 D, respectively, in post-LASIK/PRK group; and 0.03 ± 0.67 D, 0.56 ± 0.70 D and 1.40 ± 0.76 D, respectively, in keratoconus group. The calculated keratometric index is negatively related to the ratio of anterior corneal curvature to posterior corneal curvature in untreated, post-LASIK/PRK, and keratoconus eyes, respectively. Using the calculated keratometric index may improve the prediction accuracies of total corneal powers in untreated controls, but not in post-LASIK/PRK and keratoconus eyes.
Medical subject headings
- Cornea
- Keratoconus
- Refraction, Ocular
- Tomography, Optical Coherence