Vacuum-Assisted Closure for Episiotomy Dehiscence.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 25923027.
- Also identified by DOI 10.1097/AOG.0000000000000785.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Episiotomy dehiscence can result in a large vulvovaginal defect not amenable to delayed primary closure. A 26-year-old woman who underwent a forceps-assisted vaginal delivery with mediolateral episiotomy presented on postpartum day 5 with complete wound breakdown. Surgical exploration of the wound revealed a defect extending from the perineum into the vagina and deep into the ischiorectal fossa with poor tissue quality not amenable to a timely delayed primary closure. A vacuum-assisted closure device was used in lieu of traditional wound preparation and resulted in wound closure after 11 days of vacuum-assisted wound therapy. A vacuum-assisted closure device may be appropriate in cases of complex episiotomy breakdown and may expedite wound healing in the outpatient setting.
Medical subject headings
- Delivery, Obstetric
- Episiotomy
- Negative-Pressure Wound Therapy
- Surgical Wound Dehiscence