The catheter hub disinfection cap as esophageal foreign body.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 26109176.
- Also identified by DOI 10.1002/lary.25339.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Disinfection caps are increasingly being used to prevent catheter-associated bloodstream infections. These devices, designed for continuous passive disinfection of catheter hubs, are typically small and often brightly colored. As such, they have the potential to become pediatric airway and esophageal foreign bodies. We report two patients who developed esophageal foreign body following ingestion of disinfection caps. Given the increasing use of these devices, it is imperative that health care providers be aware of this potential iatrogenic problem. We propose that the use of disinfection caps may not be appropriate in pediatric patients with risk factors for foreign body ingestion.
Medical subject headings
- Catheter-Related Infections
- Catheterization, Central Venous
- Disinfection
- Esophagus
- Foreign Bodies