Arthroscopic Repair of Massive Cuff Tears With Large Subscapularis Tendon Ruptures (Lafosse III/IV): A Prospective Magnetic Resonance Imaging-Controlled Case Series of 26 Cases With a Minimum Follow-up of 1 Year.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 26188785.
- Also identified by DOI 10.1016/j.arthro.2015.05.012.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
To prospectively assess arthroscopic repair of massive cuff tears (MCT) in a highly selective patient group with large subscapularis (SSC) tendon tears by means of clinical results and magnetic resonance imaging (MRI) studies. Between April 2009 and December 2010, 26 patients with MCT were treated with arthroscopic rotator cuff repair. Only lesions involving a large tear of the SSC tendon (Lafosse III or IV) in combination with a complete tear of the supraspinatus (SSP) tendon and a tear of at least the anterior third of the infraspinatus (ISP) tendon were included. Minimum follow-up was 1 year. Pre- and postoperative assessment included a standardized clinical examination, subjective patient outcome, and MRI (structural integrity, fatty muscle infiltration, and muscular mass). Mean follow-up was 17 months (range, 12 to 34 months). MRI was performed in 25 patients. In 21 (84%) the cuff repair was intact. A partial retear of the SSC was found in 2 patients (8%). In 2 patients (8%) a full-thickness retear of the posterosuperior cuff was observed (1 SSP, 1 SSP/ISP). A significant increase of the muscle mass and decrease of fatty infiltration was observed for the SSC and SSP but not for the ISP. The mean Constant-Murley score improved from 36 to 86 points (P < .001) with all its subscores as well (P < .001). Muscular strength improved for the SSC (4.9 v 3.0, P < .001), SSP (4.6 v 2.9, P < .001), and ISP (4.8 v 3.4, P < .001). Overall patient satisfaction was high (3.6 ± 0.8). Arthroscopic repair of MCT involving the ISP, SSP, and large tears of the SSC provides a reliable tendon healing, in particular for the SSC tendon, combined with good functional results. Level IV, therapeutic case series.
Medical subject headings
- Arthroscopy
- Forecasting
- Magnetic Resonance Imaging
- Rotator Cuff
- Tendon Injuries
Anatomy
- shoulder
- scapula