Treatment of wide-necked basilar tip aneurysm not amenable to Y-stenting using the PulseRider device.
case_report · Level V
Where this comes from
- Record sourced from PubMed, PMID 26206805.
- Also identified by DOI 10.1136/neurintsurg-2015-011836.rep.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Endovascular treatment of broad-necked bifurcation aneurysms remains challenging. Stent-assisted coiling has been successful but requires catheterization of the branches off the parent vessel. We present the case of a patient who failed primary and stent-assisted coiling of a large basilar tip aneurysm because the morphology of the aneurysm precluded successful distal catheterization of the posterior cerebral artery (PCA) branches. Using the PulseRider device, which does not require catheterization of bifurcation branches, we were able to treat the aneurysm successfully.
Medical subject headings
- Embolization, Therapeutic
- Intracranial Aneurysm
- Stents
- Treatment Failure