The Rapid Screening of Triazophos Residues in Agricultural Products by Chemiluminescent Enzyme Immunoassay.
Where this comes from
- Record sourced from PubMed, PMID 26218576.
- Also identified by DOI 10.1371/journal.pone.0133839 and PMC identifier 4517747.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
A highly sensitive chemiluminescent enzyme immunoassay (CLEIA) method was developed in this study for efficient screening of triazophos residues in a large number of samples. Based on the maximum residue limits (MRLs) set by China and CAC for triazophos in different agro-products, the representative apple, orange, cabbage, zucchini, and rice samples were selected as spiked samples, and the triazophos at the concentrations of the MRL values were spiked to blank samples. Subsequently, the five samples with the spiked triazophos standard were measured by CLEIA 100 times, and the detection results indicated that the correction factors of the apple, orange, cabbage, zucchini, and rice were determined as 0.79, 0.66, 0.85, 0.76, and 0.91, respectively. In this experiment, 1500 real samples were detected by both the CLEIA and the GC-MS methods. With the GC-MS method, 1462 samples were identified as negative samples and 38 samples as positive samples. Based on the correction factors, the false positive rate of the CLEIA method was 0.13%, and false negative rate was 0. The results showed that the established CLEIA method could be used to screen a large number of real samples.
Medical subject headings
- Fruit
- High-Throughput Screening Assays
- Immunoenzyme Techniques
- Luminescent Measurements
- Organothiophosphates
- Triazoles
- Vegetables