An in silico method to identify computer-based protocols worthy of clinical study: An insulin infusion protocol use case.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 26228765.
- Also identified by DOI 10.1093/jamia/ocv067 and PMC identifier 5009926.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Develop an efficient non-clinical method for identifying promising computer-based protocols for clinical study. An in silico comparison can provide information that informs the decision to proceed to a clinical trial. The authors compared two existing computer-based insulin infusion protocols: eProtocol-insulin from Utah, USA, and Glucosafe from Denmark. The authors used eProtocol-insulin to manage intensive care unit (ICU) hyperglycemia with intravenous (IV) insulin from 2004 to 2010. Recommendations accepted by the bedside clinicians directly link the subsequent blood glucose values to eProtocol-insulin recommendations and provide a unique clinical database. The authors retrospectively compared in silico 18,984 eProtocol-insulin continuous IV insulin infusion rate recommendations from 408 ICU patients with those of Glucosafe, the candidate computer-based protocol. The subsequent blood glucose measurement value (low, on target, high) was used to identify if the insulin recommendation was too high, on target, or too low. Glucosafe consistently provided more favorable continuous IV insulin infusion rate recommendations than eProtocol-insulin for on target (64% of comparisons), low (80% of comparisons), or high (70% of comparisons) blood glucose. Aggregated eProtocol-insulin and Glucosafe continuous IV insulin infusion rates were clinically similar though statistically significantly different (Wilcoxon signed rank test P = .01). In contrast, when stratified by low, on target, or high subsequent blood glucose measurement, insulin infusion rates from eProtocol-insulin and Glucosafe were statistically significantly different (Wilcoxon signed rank test, P < .001), and clinically different. This in silico comparison appears to be an efficient nonclinical method for identifying promising computer-based protocols. Preclinical in silico comparison analytical framework allows rapid and inexpensive identification of computer-based protocol care strategies that justify expensive and burdensome clinical trials.
Medical subject headings
- Computer Simulation
- Drug Therapy, Computer-Assisted
- Hyperglycemia
- Insulin