Does Robotic-Assisted Computer Navigation Affect Acetabular Cup Positioning in Total Hip Arthroplasty in the Obese Patient? A Comparison Study.
retrospective_cohort · Level III
Where this comes from
- Record sourced from PubMed, PMID 26253480.
- Also identified by DOI 10.1016/j.arth.2015.06.062.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Obese populations present challenges for acetabular cup placement during total hip arthroplasty (THA). This study examines the accuracy of acetabular cup inclination and version in the obese patient with robotic-assisted computer navigation. A total of 105 patients underwent robotic-assisted computer navigation THA with a posterior approach. Groups were divided on body mass index (BMI, kg/m(2)) of <30, 30-35, and >35. There was no statistical difference between the BMI <30 (n=59), BMI 30-35 (n=34) and BMI >35 (n=12) groups for acetabular inclination (P=0.43) or version (P=0.95). Robotic-assisted computer navigation provided accurate and reproducible placement of the acetabular cup within safe zones for inclination and version in the obese patient.