Monitoring Central Venous Catheter Resistance to Predict Imminent Occlusion: A Prospective Pilot Study.
prospective_cohort · Level II
Where this comes from
- Record sourced from PubMed, PMID 26322512.
- Also identified by DOI 10.1371/journal.pone.0135904 and PMC identifier 4555832.
- Licence recorded as CC BY.
- The licence permits redistribution, so the abstract is shown in full and the full text is available from the publisher.
Abstract
BACKGROUND: Long-term central venous catheters are essential for the management of chronic medical conditions, including childhood cancer. Catheter occlusion is associated with an increased risk of subsequent complications, including bloodstream infection, venous thrombosis, and catheter fracture. Therefore, predicting and pre-emptively treating occlusions should prevent complications, but no method for predicting such occlusions has been developed. METHODS: We conducted a prospective trial to determine the feasibility, acceptability, and efficacy of catheter-resistance monitoring, a novel approach to predicting central venous catheter occlusion in pediatric patients. Participants who had tunneled catheters and were receiving treatment for cancer or undergoing hematopoietic stem cell transplantation underwent weekly catheter-resistance monitoring for up to 12 weeks. Resistance was assessed by measuring the inline pressure at multiple flow-rates via a syringe pump system fitted with a pressure-sensing transducer. When turbulent flow through the device was evident, resistance was not estimated, and the result was noted as "non-laminar." RESULTS: Ten patients attended 113 catheter-resistance monitoring visits. Elevated catheter resistance (>8.8% increase) was strongly associated with the subsequent development of acute catheter occlusion within 10 days (odds ratio = 6.2; 95% confidence interval, 1.8-21.5; p <0.01; sensitivity, 75%; specificity, 67%). A combined prediction model comprising either change in resistance greater than 8.8% or a non-laminar result predicted subsequent occlusion (odds ratio = 6.8; 95% confidence interval, 2.0-22.8; p = 0.002; sensitivity, 80%; specificity, 63%). Participants rated catheter-resistance monitoring as highly acceptable. CONCLUSIONS: In this pediatric hematology and oncology population, catheter-resistance monitoring is feasible, acceptable, and predicts imminent catheter occlusion. Larger studies are required to validate these findings, assess the predictive value for other clinical outcomes, and determine the impact of pre-emptive therapy. TRIAL REGISTRATION: Clinicaltrials.gov NCT01737554.
Medical subject headings
- Catheterization, Central Venous
- Central Venous Catheters