Real-time Imaging of the Resection Bed Using a Handheld Probe to Reduce Incidence of Microscopic Positive Margins in Cancer Surgery.
case_series · Level IV
Where this comes from
- Record sourced from PubMed, PMID 26374464.
- Also identified by DOI 10.1158/0008-5472.CAN-15-0464 and PMC identifier 4749141.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
Wide local excision (WLE) is a common surgical intervention for solid tumors such as those in melanoma, breast, pancreatic, and gastrointestinal cancer. However, adequate margin assessment during WLE remains a significant challenge, resulting in surgical reinterventions to achieve adequate local control. Currently, no label-free imaging method is available for surgeons to examine the resection bed in vivo for microscopic residual cancer. Optical coherence tomography (OCT) enables real-time high-resolution imaging of tissue microstructure. Previous studies have demonstrated that OCT analysis of excised tissue specimens can distinguish between normal and cancerous tissues by identifying the heterogeneous and disorganized microscopic tissue structures indicative of malignancy. In this translational study involving 35 patients, a handheld surgical OCT imaging probe was developed for in vivo use to assess margins both in the resection bed and on excised specimens for the microscopic presence of cancer. The image results from OCT showed structural differences between normal and cancerous tissue within the resection bed following WLE of the human breast. The ex vivo images were compared with standard postoperative histopathology to yield sensitivity of 91.7% [95% confidence interval (CI), 62.5%-100%] and specificity of 92.1% (95% CI, 78.4%-98%). This study demonstrates in vivo OCT imaging of the resection bed during WLE with the potential for real-time microscopic image-guided surgery.
Medical subject headings
- Breast Neoplasms
- Carcinoma
- Computer Systems
- Intraoperative Care
- Mastectomy
- Neoplasm, Residual
- Tomography, Optical Coherence