Is High-Flexion Total Knee Arthroplasty a Valid Concept? Bilateral Comparison With Standard Total Knee Arthroplasty.
rct · Level II
Where this comes from
- Record sourced from PubMed, PMID 26411392.
- Also identified by DOI 10.1016/j.arth.2015.09.001.
- No licence information is recorded for this record.
- Because redistribution is not established, this page shows the abstract only. Follow the links below for the full text.
Abstract
The purpose of this study was to determine whether the high-flexion total knee prosthesis significantly improves knee flexion in vivo. Forty-four patients undergoing same-day bilateral total knee arthroplasty for primary osteoarthritis of both knees were randomized to receive a standard posterior-stabilized knee prosthesis (P.F.C. Sigma; DePuy Johnson & Johnson, Warsaw, IN) in one knee and a high-flexion concept posterior-stabilized knee prosthesis (LOSPA; Corentec, Inc, Seoul, Korea) in the other knee and were followed up for 2 years postoperatively. The mean postoperative range of motion was 128.8° (range, 100°-144°) in the LOSPA group and 128.5° (range, 100°-142°) in the P.F.C. Sigma group (P = .744). There were no significant differences in the postoperative mean Knee Society score and Western Ontario and McMaster Universities Osteoarthritis Index score between the LOSPA and P.F.C. Sigma groups (P = .839 and P = .972, respectively). Despite theoretical range of motion advantages of high-flexion prosthesis, there were no group differences with regard to range of motion, clinical outcomes, and the incidence of radiolucent lines at final follow-up assessment.
Medical subject headings
- Arthroplasty, Replacement, Knee
- Knee Prosthesis
- Range of Motion, Articular
Anatomy
- knee